Installation topology (PAC hybrid installation example)
In this installation topology, fieldbus connection is made via mini I/O plug connector X42 and X43 at the connection unit. Use only electronics cover with the following connection configurations:
- DFC.1.. / DSI.1.. (M12 plug connector for digital inputs/outputs)
- DFC.2.. / DSI.2.. (Without M12 plug connector)
The following figure shows the basic PAC hybrid installation typology with a hybrid cable for line voltage, 24 V backup voltage, and communication. An optional STO signal is led separately to the unit.
[1] | Connected drive units with/without digital interface |
[2] | Decentralized drive units or decentralized inverters in communication design DFC or DSI with connection via mini I/O plug connector. |
[3] | PAC hybrid cables for line voltage, 24 V backup voltage, and Ethernet fieldbus |
[4] | Max. permitted cable length of the STO cable between safety relay and the last inverter: 100 m. |