Torque control (optional with closed-loop tension control)

The input torque is calculated taking into account the current diameter of the coil so that the tension remains constant at the winding circumference. The circumferential speed follows the lead speed here.

To enhance the tension accuracy, deviations from setpoints can be minimized with a tension sensor via a PID controller.