Requirements

The MOVIMOT® drive can only be used in hoist applications if the following prerequisites are met:

  • Additional function 13 is only possible in connection with brakemotors.
  • Make sure that DIP switch S2/3 = "OFF" (VFC operation).
  • It is mandatory to use a brake controller in connection with an external braking resistor.
  • Note the descriptions and information for additional function 9.