Requirements
The MOVIMOT® drive can only be used in hoist applications if the following prerequisites are met:
- Additional function 9 is only possible in connection with brakemotors.
- Make sure that DIP switch S2/3 = "OFF" (VFC operation).
- It is mandatory to use a brake controller in connection with an external braking resistor.
- Activate the speed monitoring function
(DIP switch S2/4 = "ON").