Requirements
With the CSL..A and CSS..A safety options, the required process values are created by selecting the encoder.
Proceed in the following order:
- Configure the drive train in the inverter with all the encoders involved and the user units.
- Open the "Assist CS.." parameterization tool and log in. The user units configured in the drive train are added to the "Assist CS.." parameterization tool.
- Apply the encoder parameters to the safe configuration.
- Configure the required safety sub-functions.
- All the limit speeds of the safety sub-functions must lie between the minimum speed and the maximum speed.