FS data fault of internal memory

The data error is triggered by faulty data in the RAM and results in a restart of the safety option.

In the case of a data error, all safe digital inputs and all safe digital outputs are switched to the safe state. In addition, the STO safety subfunction is executed without a delay. The safe state of the safety option is activated and a corresponding fault code is set.

The data error can be acknowledged via a safe digital input or safe communication.

Safe communication must first be restored for acknowledgment via safe communication.