Device replacement with MOVI-C® without PC

The MOVI-C® system offers the option to save the application-related data set for the inverter and the data set for the safety option on the memory module in the inverter or on the MOVI-C® CONTROLLER. This step must be performed in advance by the user with the MOVI-C® CONTROLLER.

The following steps must be performed for the actual device replacement:

  1. Switch off the device to be replaced.
  2. Remove the pluggable CMM memory module with integrated safety key from the device.
  3. Replace the device (including MOVISAFE® CS..A safety option).
  4. Reinsert the CMM memory module with integrated safety key that was removed in step 2.
  5. Carry out a functional test. The checking of all parameters is omitted.

The controller/inverter automatically detects the device replacement and loads the application data set into the MOVISAFE® CS..A safety option. The localized key data set on the pluggable safety key ensures that the correct application data set has been loaded. The MOVISAFE® CS..A safety option is then in the same state that it was in before the device replacement. This means that if the MOVISAFE® CS..A safety option was in the "Accepted" state before the device replacement, it will be in the "Accepted" state again after device replacement. In order to ensure correct connection of the sensors and actuators, a function test of the safety option is required in the case of automatic device replacement function.