Overview of fault responses
Parameter designation | Description |
|---|---|
Limit switches | |
HW limit switch hit response |
|
Index: 8572.1 | |
IEC name: Parameter.LimitSwitchData1.HwLsHitResp | |
SW limit switch hit response |
|
Index: 8572.2 | |
IEC name: Parameter.LimitSwitchData1.SwLsHitResp | |
Basic settings of central stop profile | |
Error response INFORMATION: Only configurable in expert mode. | Behavior of profile generation in the event of an error:
|
Index: 50000.11 | |
IEC name: ProfileGeneration.Config.eErrorReaction | |
Anti-sway control INFORMATION: Only visible if the additional functions "Position controller" and "Anti-sway control" are activated. | |
Setpoint position response of the lifting axis not initialized (E120.24) INFORMATION: Only configurable in expert mode. | If the travel axis is intended to be moved with the activated anti-sway control without the lifting axis being previously enabled once, the following fault response can be configured:
Note that the position of the lifting axis cannot be determined if the lifting axis is not enabled once after the MOVI-C® CONTROLLER is switched off or on. In this case, it is assumed that the lifting position is at the maximum height of the tower (worst case). |
Index: 50010.202 | |
IEC name: – | |
Timeouts INFORMATION: Only visible if the additional function "Position controller" is activated. | |
Response to INFORMATION: Only configurable in expert mode. | Select the fault response that is executed when the cycle time is exceeded 1000× in succession:
|
Index: 50010.203 | |
IEC name: – | |
Response to application INFORMATION: Only configurable in expert mode. |
|
Index: 8622.21 | |
IEC name: Parameter.ParameterizableFaultResponse.ProgTimeoutApplicationHeartbeat | |