Limit switches

 

Parameter designation

Description

Software limit switches

Monitoring
negative SW limit switch

Activate the function for monitoring the negative software limit switch.

Default value: Off

Index: 8572.3, Bit0

IEC name: LimitSwitchEvaluation.SoftwareLimitSwitch.In.xActivateMonitoringNegative

SW limit switch negative

Position of the negative software limit switch

(in user units)

Index: 8572.4

IEC name: LimitSwitchEvaluation.SoftwareLimitSwitch.In.lrLimitNegative

Monitoring
positive SW limit switch

Activate the function for monitoring the positive software limit switch.

Default value: Off

Index: 8572.5

IEC name: LimitSwitchEvaluation.SoftwareLimitSwitch.In.xActivateMonitoringPositive

SW limit switch positive

Position of the positive software limit switch

(in user units)

Index: 8572.6, Bit0

IEC name: LimitSwitchEvaluation.SoftwareLimitSwitch.In.lrLimitPositive

SW limit switches for position controller (monitored on the MOVI-C® CONTROLLER)

INFORMATION: Only visible if the additional function "Position controller" is activated.

Monitoring
negative SW limit switch

Activate the function for monitoring the negative software limit switch.

Default value: Off

Index: 50015.41, Bit0

IEC name: SoftwareLimitSwitch.xActivateMonitoringNegative

SW limit switch negative

Position of the negative software limit switch

(in user units)

Index: 50015.42

IEC name: –

Monitoring
positive SW limit switch

Activate the function for monitoring the positive software limit switch.

Default value: Off

Index: 50015.43, Bit0

IEC name: SoftwareLimitSwitch.xActivateMonitoringPositive

SW limit switch positive

Position of the positive software limit switch

(in user units)

Index: 50015.44

IEC name: –

Error response

SW limit switch hit response

  • No response
  • Warning
  • Emergency stop + output stage inhibit
  • Emergency stop + output stage inhibit with self-reset

Index: 8572.2

IEC name: Parameter.LimitSwitchData1.SwLsHitResp

HW limit switch hit response

  • No response
  • Emergency stop + output stage inhibit
  • Emergency stop + output stage inhibit with self-reset

Index: 8572.1

IEC name: Parameter.LimitSwitchData1.HwLsHitResp

Actual values in user units

Position

Actual position

(in user units)

Index: 8364.26

IEC name:

Modulo position

Actual position within the modulo positioning range

(in user units)

Index: 8364.27

IEC name:

Active drive referenced

Indicates whether the active drive is referenced.

Index: 8332.1, Bit6

IEC name:

Open manual mode

Button "Open manual mode to determine SW limit switch"

In manual mode, the drive can be moved to determine the SW limit switches.