Encoder evaluation
Note that this configuration menu is only displayed if the function is activated in the "Basic settings" configuration menu under "Additional functions".
Note that the modulo reference may be lost when an encoder error is acknowledged.
Parameter designation | Description |
|---|---|
Position controller | |
Encoder source | Selection of the encoder source:
An encoder that has a lower resolution than a motor encoder for the same distance is referred to as a low-resolution encoder or external encoder. An encoder that has a resolution similar to that of a motor encoder for the same distance is referred to as a high-resolution encoder. |
Index: 50013.1 | |
IEC name: Controller.EncoderEvaluation.Config.eActPos_EncSelector | |
Settings of external encoders INFORMATION: Only visible if encoder source is "External encoder" or "Motor encoder and external encoder". | |
Type | Select whether the external encoder on the inverter is read via an option card or via the MOVIKIT® EncoderInterface:
|
Index: 50013.9 | |
IEC name: Controller.EncoderEvaluation.Config.eActPos_EncSelector | |
Source of EtherCAT® encoder INFORMATION: Only visible if type is "EtherCAT® encoder". | Selection of the name of the EncoderInterface that is to be considered the encoder source of the respective member. If the EtherCAT® encoder is only required for the position controller, it is sufficient to connect "Source of EtherCAT® encoder axis group member 1". |
Index: 50013.10 | |
IEC name: – | |
New initialization of encoder when changing encoder source INFORMATION: Only visible in expert mode. | Activate reinitialization of encoder when changing encoder source Default value: Yes |
Index: 50013.6 | |
IEC name: Controller.EncoderEvaluation.Config.xDontInitializeAtEncSelectorChange | |
Time constant | Integral time for encoder adjustment (in s) Default value: 0 |
Index: 50013.3 | |
IEC name: Controller.EncoderEvaluation.Config.lrInputFilterTime_ExtEnc | |
Dead time INFORMATION: Only visible in expert mode. | Dead time of the external encoder (in s) Contact SEW‑EURODRIVE or the manufacturer of the external encoder to obtain the relevant value. Default value: 0 |
Index: 50013.4 | |
IEC name: Controller.EncoderEvaluation.Config.lrDeadtime_ExtEnc | |