F-communication when activated

The F-communication when activated parameter defines the behavior of safe communication with the higher-level safety controller when the prioritized terminal control is activated.

Parameter

Setting

Meaning

F-communication when activated

Yes

Safe communication is interrupted when the prioritized terminal control is activated.

The signals of the higher-level safety controller are no longer active on the inverter.

This causes the safety card to signal a safe communication timeout error and the safety sub-functions are activated.

 

The "Muting F-PO" function can be used to deactivate the safety sub-functions and thus enable the drive again.

No

Safe communication is not interrupted when the prioritized terminal control is activated.

The signals of the higher-level safety controller are still active on the inverter.