Standard error responses on the MDA90A.. and MDD9.A.. axis modules
Error response | Description |
|---|---|
No response | The axis module ignores the event. |
Warning with self reset | The axis module sends a warning message with self-reset. The error is automatically reset after the cause of the error is eliminated. |
Warning | The axis module issues a warning message. |
Application stop (with output stage inhibit) | The axis module stops with the deceleration set for the application limit. Parameter set 1 Index 8375.0-13 Parameter set 2 Index 8375.8-13 If n = 0: Brake "applied" and output stage "off". |
Application stop (with output stage inhibit) with self-reset | |
Emergency stop (with output stage inhibit) | The axis module stops with the set emergency stop deceleration. Parameter set 1 Index 8375.0-20 Parameter set 2 Index 8375.8-20 |
Emergency stop (with output stage inhibit) with self-reset | |
Inhibit output stage with self-reset | The output stage is deactivated and the brake is applied. |
Inhibit output stage |
Self-reset means: Eliminating the cause of the error results in the acknowledgment of the error. The inverter automatically resumes the operation performed before the error. The drive can restart automatically.