Error 6 Line fault
Error: 6.1 (0601hex | 1537dec) Description: Line phase failure | ||
|---|---|---|
| Response: Line phase failure | |
Cause | Measure | |
Line phase missing. | Check the power supply cable. | |
Poor line voltage quality. | Check supply (fuses, contactor, line components). | |
DC link voltage periodically too low. | Check the line voltage. | |
Error: 6.2 (0602hex | 1538dec) Description: Power failure | ||
|---|---|---|
| Response: Power failure | |
Cause | Measure | |
Power failure detected. | Check the power supply cable. | |
Error: 6.3 (0603hex | 1539dec) Description: Line overvoltage | ||
|---|---|---|
| Response: Output stage inhibit (standard) | |
Cause | Measure | |
Line voltage exceeds permitted upper threshold value. | Check the nominal line voltage in the project planning. | |
Poor line voltage quality. | Check the quality of the power system. | |
Error: 6.4 (0604hex | 1540dec) Description: Line undervoltage | ||
|---|---|---|
| Response: Line undervoltage | |
Cause | Measure | |
Line voltage dropped below permitted lower threshold value. | Check the nominal line voltage in the project planning. | |
Poor line voltage quality. | Check the quality of the power system. | |