Error 6 Line fault

Error: 6.1 (0601hex | 1537dec)

Description: Line phase failure

 

Response: Line phase failure

Cause

Measure

Line phase missing.

Check the power supply cable.

Poor line voltage quality.

Check supply (fuses, contactor, line components).

DC link voltage periodically too low.

Check the line voltage.

Error: 6.2 (0602hex | 1538dec)

Description: Power failure

 

Response: Power failure

Cause

Measure

Power failure detected.

Check the power supply cable.

Error: 6.3 (0603hex | 1539dec)

Description: Line overvoltage

 

Response: Output stage inhibit (standard)

Cause

Measure

Line voltage exceeds permitted upper threshold value.

Check the nominal line voltage in the project planning.

Poor line voltage quality.

Check the quality of the power system.

Error: 6.4 (0604hex | 1540dec)

Description: Line undervoltage

 

Response: Line undervoltage

Cause

Measure

Line voltage dropped below permitted lower threshold value.

Check the nominal line voltage in the project planning.

Poor line voltage quality.

Check the quality of the power system.