Assignment of the maximum axis size
Axis modules up to the following maximum axis module size may be connected to the MDP92A.. power supply modules:
Device | Largest permitted axis | ||||
|---|---|---|---|---|---|
Without MDC | MDC90A-0005.. | MDC92A-0075.. | MDC90A-0120.. | MDC92A-0125.. | |
MDP92A-0100.. | MDA90A-0240.. | MDA90A-1400.. | MDA90A-1400.. | MDA90A-1000.. | MDA90A-1800.. |
MDP92A-0250.. | MDA90A-1400.. | MDA90A-1800.. | MDA90A-1400.. | MDA90A-1000.. | MDA90A-1800.. |
The MDD9.A.. double-axis modules are permissible regardless of the size of the MDP92A.. power supply module and the capacitor module.