Arrangement of the modules

The modules can be arranged in one or two rows.

Single-row setup

Position

Description

-2

MDS90A.. switched-mode power supply module

-1

Master module UHX45A/MDM90A

0

MDP90A.. power supply module

1

Axis modules MDA90A.. and MDD9.A..

Observe the following information:

  • Always arrange the MDA90A.. and MDD9.A.. axis modules directly to the right of the MDP90A.. power supply module, based on the nominal DC link current (descending) from left to right, starting with the axis module with the highest nominal DC link current.
  • As an alternative to the specification in the table, you can arrange the UHX45A/MDM90A master module to the far right.
  • The position of the UHX45A/MDM90A master module and the MDS90A.. switched-mode power supply module can be switched.
Two-row setup
Auxiliary row

Position

Description

0

MDC90A-0001/002.. capacitor modules

1

Axis modules MDA90A.. and MDD9.A..

2

UHX45A/MDM90A master module

3

MDS90A.. switched-mode power supply module

Main row

Position

Description

0

MDP90A.. power supply module

1

Axis modules MDA90A.. and MDD9.A..

2

MDS90A.. switched-mode power supply module

Observe the following information:

  • Always arrange the MDP90A.. power supply module to the far left in the main row.
  • Always arrange the MDA90A.. and MDD9.A.. axis modules in the main row directly to the right of the MDP90A.. power supply module, based on the nominal DC link current (descending) from left to right, starting with the axis module with the highest nominal DC link current.
  • Always arrange the MDC90A-0001/0002.. capacitor modules to the far left In the auxiliary row.
  • Always arrange the MDA90A.. and MDD9.A.. axis modules in the auxiliary row directly to the right of the MDC90A-0001/0002.. capacitor modules, based on the nominal DC link current (descending) from left to right, starting with the axis module with the highest nominal DC link current.
  • Arrange the UHX45A/MDM90A master module in the auxiliary row to the right of the axis modules. As an alternative to the specification in the table, you can also arrange the UHX45A/MDM90A master module to the right of the axis modules in the main row.
  • Place an MDS90A.. switched-mode power supply module to the far right in the main or auxiliary row.