Temperature monitoring of MDC90A-0120.. capacitor module

The MDC90A-0120-.. capacitor module can optionally be equipped with a temperature sensor. When using a temperature sensor, the temperature limits at which a shutdown is to take place or a warning is to be issued must be specified during the startup process.

Implement all of the necessary settings in MOVISUITE® by selecting the menu: "MOVIKIT® PowerMode/EnergyMode" → "Energy storage unit"→ "Local storage unit interface":

  • Select "PT1000" as the sensor type.
  • Enter 65 °C as the switch-off threshold for the maximum temperature.
  • Enter -40 °C as the switch-off threshold for the minimum temperature.
  • Enter a hysteresis value of 10 K in order to receive a warning when the temperature reaches 55 °C.