Default error responses on the MDP92A.. power supply module and the MDE90A.. DC/DC converter module

Error response

Description

No response

The power supply module ignores the event.

Warning with self reset

The power supply module sends a warning message with self-reset. The error is automatically reset after the cause of error is eliminated.

Warning

The power supply module issues a warning message.

Output stage inhibit (standard)

The output stage is deactivated.

Output stage inhibit (critical)

The output stage is deactivated.

Inhibit brake chopper

The output stage and the brake chopper are deactivated.

Self-reset means: Eliminating the cause of the error results in acknowledgment of the error. The power supply module automatically resumes the operation performed before the error. The voltage and current can increase automatically.