Error 108 MOVIKIT® – EncoderInterface

Error: 108.64 (6C40hex | 27712dec)

Description: Configuration parameter missing

 

 

Cause

Measure

Failed to find a required parameter in the configuration file.

– Check the configuration of the individual operating modes.

– In MOVISUITE® in the parameter setting of the controller under [Data management], download the data by clicking "Update configuration data".

Error: 108.65 (6C41hex | 27713dec)

Description: No external variable linked

 

 

Cause

Measure

The link of an input variable, a SendObject or an external source to the MOVIKIT® encoder interface is missing.

Link input variable.

Error: 108.66 (6C42hex | 27714dec)

Description: Value outside valid numerical range

 

 

Cause

Measure

The error can be caused as follows:

– The multiplication of the number of decimal places and the value in IrSetValue is outside the valid range of values.

– The denominator of the user units set for MOVIKIT® EncoderInterface is 0.

– Set decimal place or IrSetValue smaller.

or

– Set denominator of the user units > 0.

Error: 108.70 (6C46hex | 27718dec)

Description: Interface to the persistent data not linked

 

 

Cause

Measure

Internal error

Contact SEW-EURODRIVE Service.

Error: 108.71 (6C47hex | 27719dec)

Description: No external variable linked

 

 

Cause

Measure

The external source link is missing.

Link input variable.

Error: 108.72 (6C48hex | 27720dec)

Description: Configuration data interface not linked

 

 

Cause

Measure

Internal error

Contact SEW-EURODRIVE Service.

Error: 108.73 (6C49hex | 27721dec)

Description: Interface not linked

 

 

Cause

Measure

Internal error

Contact SEW-EURODRIVE Service.

Error: 108.74 (6C4Ahex | 27722dec)

Description: Deviation from persistently stored value and current value

 

 

Cause

Measure

The input variable, SendObject or external source deviates too much from the stored value after the controller has started up.

Increase or switch off warning limit (= 0).