Fault 11 Temperature monitoring

Fault: 11.1 (0B01hex | 2817dec)

Description: Heat sink overtemperature

 

Response: Output stage inhibit

Cause

Measure

Utilization too high. Maximum permitted heat sink temperature exceeded.

– Reduce the load.

– Reduce the PWM frequency.

– Reduce the ambient temperature.

Air circulation disrupted. Maximum permitted heat sink temperature exceeded.

– Check the air circulation.

– Ensure sufficient cooling.

The fan (if present) is defective. The maximum permitted heat sink temperature has been exceeded.

Contact SEW-EURODRIVE Service.

Temperature sensor defective. Maximum permitted heat sink temperature exceeded.

Contact SEW-EURODRIVE Service.

The fan (if present) is blocked or dirty.

– Remove foreign objects.

– Clean the fan.

Fault: 11.2 (0B02hex | 2818dec)

Description: Heat sink utilization – prewarning

 

Response: Heat sink utilization – prewarning

Cause

Measure

High thermal load on heat sink of device. Prewarning threshold reached.

– Reduce the load.

– Reduce the PWM frequency.

– Reduce the ambient temperature.

Air circulation disrupted. Prewarning threshold reached.

– Check the air circulation.

– Ensure sufficient cooling.

Fan (if available) defective. Prewarning threshold reached.

Contact SEW-EURODRIVE Service.

Temperature sensor defective. Prewarning threshold reached.

Contact SEW-EURODRIVE Service.

Air convection is unfavorable.

Check air convection.

The fan (if present) is blocked or dirty.

– Remove foreign objects.

– Clean the fan.

Fault: 11.3 (0B03hex | 2819dec)

Description: Device utilization

 

Response: Output stage inhibit

Cause

Measure

Mean output current too high. Device utilization has reached or exceeded the switch-off threshold.

– Reduce the load.

– Check the combination of motor and inverter.

PWM frequency too high. Device utilization has reached or exceeded the switch-off threshold.

Reduce the PWM frequency.

Ambient temperature too high. Device utilization has reached or exceeded the switch-off threshold.

Reduce the ambient temperature.

Air circulation disrupted. Device utilization has reached or exceeded the switch-off threshold.

– Check the air circulation.

– Ensure sufficient cooling.

Fan (if installed) defective. Device utilization has reached or exceeded the switch-off threshold.

Contact SEW-EURODRIVE Service.

The fan (if present) is blocked or dirty.

– Remove foreign objects.

– Clean the fan.

Fault: 11.5 (0B05hex | 2821dec)

Description: Electromechanical utilization

 

Response: Output stage inhibit

Cause

Measure

Electromechanical components of device overloaded by excessive continuous current.

Reduce the load.

Fault: 11.6 (0B06hex | 2822dec)

Description: Electromechanical utilization – prewarning

 

Response: Electromechanical utilization – prewarning

Cause

Measure

High load on electromechanical components of device due to high continuous current. Prewarning threshold reached.

Reduce the load.

Fault: 11.7 (0B07hex | 2823dec)

Description: Wire break at temperature sensor of heat sink

 

Response: Output stage inhibit

Cause

Measure

Wire break at temperature sensor of heat sink.

Contact SEW-EURODRIVE Service.

Fault: 11.8 (0B08hex | 2824dec)

Description: Short circuit at temperature sensor of heat sink

 

Response: Output stage inhibit

Cause

Measure

Short circuit at temperature sensor of motor.

Contact SEW-EURODRIVE Service.

Fault: 11.9 (0B09hex | 2825dec)

Description: Overtemperature of signal electronics

 

Response: Output stage inhibit

Cause

Measure

Maximum permitted signal electronics temperature exceeded.

– Reduce the load.

– Reduce the ambient temperature.

Fault: 11.10 (0B0Ahex | 2826dec)

Description: Wire break at temperature sensor of signal electronics

 

Response: Output stage inhibit

Cause

Measure

Wire break at temperature sensor of signal electronics.

Contact SEW-EURODRIVE Service.

Fault: 11.11 (0B0Bhex | 2827dec)

Description: Short circuit at temperature sensor of signal electronics

 

Response: Output stage inhibit

Cause

Measure

Short circuit at temperature sensor of motor.

Contact SEW-EURODRIVE Service.