连接负载

表格显示了所安装加热元件的功率。

减速机

P安装

P安装

1个加热元件

2个加热元件

规格

规格

kW

K/h

kW

K/h

X100

 

X2F、X2K、X3K

1 x 0.4

6

2 x 0.4

11

X3F

1 x 0.3

3

2 x 0.3

7

X110

 

X2F、X2K、X3K

1 x 0.6

6

X3F

1 x 0.3

4

X120

 

 

X2K

1 x 0.6

6

2 x 0.6

11

X2F、X3K、X3F、X4K

1 x 0.7

6

2 x 0.7

11

X4F

1 x 0.3

3

2 x 0.3

5

X130

 

X2F、X2K、X3K、X3F、X4K

1 x 0.7

5

X4F

1 x 0.4

3

X140

X2K

1 x 0.7

4

2 x 0.7

9

X2F、X3K、X3F、X4K

1 x 0.8

5

2 x 0.8

10

X4F

1 x 0.4

3

2 x 0.4

5

X150

X2K

1 x 0.8

5

X2F、X3K、X3F、X4K

1 x 0.9

5

X4F

1 x 0.6

3

X160

X2K

1 x 0.9

4

2 x 0.9

8

X2F、X3K、X3F、X4K

1 x 1.1

4

2 x 1.1

8

X4F

1 x 0.7

3

2 x 0.7

5

X170

X2K

1 x 0.9

4

X2F、X3K、X3F、X4K

1 x 1.1

4

X4F

1 x 0.7

3

X180

X2F、X2K、X3K、X3F、X4K

1 x 1.6

5

2 x 1.6

10

X4F

1 x 1.1

4

2 x 1.1

7

X190

X2F、X2K、X3K、X3F、X4K

1 x 1.6

5

X4F

1 x 1.1

3

X200

X2K

1 x 1.6

4

2 x 1.6

8

X2F、X3K、X3F

1 x 1.8

4

2 x 1.8

8

X4F

1 x 1.3

3

2 x 1.3

6

X210

X2K

1 x 1.5

4

X2F、X3K、X3F、X4K

1 x 1.8

4

X4F

1 x 1.3

3

X220

X2K

1 x 1.8

3

2 x 1.8

7

X2F、X3K、X3F、X4F、X4K

1 x 2.2

4

2 x 2.2

8

X230

X2K

1 x 1.8

3

X2F、X3K、X3F、X4F、X4K

1 x 2.2

4

X240

X2K

1 x 1.8

3

2 x 1.8

5

X2F、X3K、X3F、X4F、X4K

1 x 2.2

3

2 x 2.2

6

X250

X2K

1 x 2.2

3

X2F、X3K、X3F、X4F、X4K

1 x 2.6

3

X260

X2F、X3K、X3F、X4F、X4K

1 x 3.8

4

2 x 3.8

8

X270

X2F、X3K、X3F、X4F、X4K

1 x 3.8

4

X280

X2F、X3K、X3F、X4F、X4K

1 x 4.2

4

X290

X2F、X3K、X3F、X4F、X4K

1 x 4.2

3

2 x 4.2

6

X300

X2F、X3K、X3F、X4F、X4K

1 x 4.2

3

X310

X2F、X3K、X3F、X4F、X4K

1 x 5.0

3

2 x 5.0

6

X320

X2F、X3K、X3F、X4F、X4K

1 x 5.0

3

K/h

= 加热功率(单位:开尔文/小时)

P安装

= 加热体的安装功率