Fault 12 Brake

Fault: 12.13 (0C0Dhex | 3085dec)

Description: Faulty voltage

 

Response: Output stage inhibit

Cause

Measure

The voltage of the brake output is not compatible with the nominal voltage of the brake that was started up.

– Check brake startup.

or

– Use device with appropriate brake voltage.

or

– Use drive with appropriate brake.

Fault: 12.20 (0C14hex | 3092dec)

Description: Digital motor integration – critical fault

 

Response: Output stage inhibit with self-reset

Cause

Measure

The intelligent brake rectifier of digital motor integration has detected a critical fault.

Observe the fault message of the subslave. Identify the exact cause of this fault message and take the appropriate measures to eliminate the fault.

Fault: 12.21 (0C15hex | 3093dec)

Description: Digital motor integration – fault

 

Response: Emergency stop + output stage inhibit with self-reset

Cause

Measure

The intelligent brake rectifier of digital motor integration has detected a fault.

Observe the fault message of the subslave. Identify the exact cause of this fault message and take the appropriate measures to eliminate the fault.

Fault: 12.22 (0C16hex | 3094dec)

Description: Digital motor integration – warning

 

Response: Warning with self-reset

Cause

Measure

The intelligent brake rectifier of digital motor integration has signaled a warning.

Observe the warning of the subslave. Identify the exact cause of this warning and take the appropriate measures for elimination.

Fault: 12.23 (0C17hex | 3095dec)

Description: Digital motor integration – timeout

 

Response: Output stage inhibit

Cause

Measure

Communication with the intelligent brake rectifier is disrupted.

Check the connection.

Fault: 12.24 (0C18hex | 3096dec)

Description: Digital motor integration – initialization error

 

Response: Output stage inhibit

Cause

Measure

Initialization of the intelligent brake rectifier has failed.

– Acknowledge the fault.