Fieldbus interface
INFORMATION

If an axis group member uses the MOVIKIT® Gearing, you can find more information on this in chapter MOVIKIT® Gearing as axis group member.
Parameter designation | Description |
|---|---|
Fieldbus configuration | |
Activate fieldbus connection | Activate fieldbus connection and automatically add MOVIKIT® fieldbus monitor to the IEC project for monitoring and controlling the fieldbus interface. |
Index: 50000.150 | |
IEC name: – | |
Start address | Start address of the process data in the array of the bus system. Counting starts at 1 |
Index: 50000.151 | |
IEC name: – | |
Basic process data | Number of pieces of process data for the software module without activated "Additional functions" |
Index: 50000.159 | |
IEC name: – | |
Optional process data | Additional process data of the activated "Optional process data" |
Index: 50000.163 | |
IEC name: – | |
Additional process data user program | Additional process data that is not occupied by the software module and can be freely assigned by the user. The assignment of this process data must be programmed in the IEC program. |
Index: 50000.160 | |
IEC name: - | |
Process data length | Resulting length of the process data of the software module |
Index: – | |
IEC name: – | |
Optional process data – See Process output data and Process input data | |
Control word/status word 2 | Selection of the priority of compensation |
Index: 50000.167 | |
IEC name: - | |
Tension between member 1 and 2 | Specification of a tension between axis group members 1 and 2, for example when reaching the target. |
Index: 50000.168 | |
IEC name: - | |
Load distribution | Specification of a load distribution between axis group members 1 to 4. When using load distribution, a ratio not equal to 0:0 must be transferred. |
Index: 50000.169 | |
IEC name: - | |
Position controller P gain | Specification of the P gain of the position controller if it is to be changed during operation. |
Index: 50000.170 | |
IEC name: - | |
P gain balance controller | Specification of the P gain of the balance controller if it is to be changed during operation. This is possible with the setting "Torque" and "Skew" for "Priority of compensation". |
Index: 50000.171 | |
IEC name: - | |
User-defined speed correction values | Specification of own speed correction values with the setting "User-defined speed correction values" or "User-defined speed correction values with diagnostics" for "Priority of compensation". |
Index: 50000.172 | |
IEC name: - | |
Skew offset | Specification of a symmetrical skew offset with the setting "Skew" and "Skew without overload monitor" for the "Priority of compensation" for consciously skewing individual axis group members to each other. |
Index: 50000.173 | |
IEC name: - | |
Anti-sway control | Display the additional optional process data for the "Anti-sway control" function. |
Index: 50000.174 | |
IEC name: - | |
Status word/control word
INFORMATION: Only visible when the optional anti-sway control process data word is activated. | Activating the anti-sway control and feedback whether it is still busy. Switching the anti-sway control on or off during travel is prevented and only occurs in the idle state. |
Index: 50000.175 | |
IEC name: - | |
Payload mass
INFORMATION: Only visible when the optional anti-sway control process data word is activated. | Order-related modification of the payload configuration |
Index: 50000.176 | |
IEC name: - | |
Distance between lifting trolley and traveling trolley
INFORMATION: Only visible when the optional anti-sway control process data word is activated. | Order-related change to the configuration of the distance between lifting and traveling trolley |
Index: 50000.177 | |
IEC name: - | |
Deflection of sway
INFORMATION: Only visible when the optional anti-sway control process data word is activated. | Specification of deflection of the sway (in preparation) |
Index: 50000.178 | |
IEC name: - | |
Number of axis group members of the MultiAxisController | Specification of the number of axis group members of the software module to obtain additional actual values of the axis group members on the fieldbus interface. |
Index: 50000.153 | |
IEC name: - | |
Access control | Control access via fieldbus. This makes it possible to move the software module separately if the MOVIKIT® MultiAxisController or Robotics is located at a higher level. |
Index: 50000.185 | |
IEC name: - | |
Coupling monitoring | Show additional optional process data for the "Coupling monitoring" function. |
Index: 5000050000.188 Bit 0 | |
IEC name: - | |
Maximum value of the encoder difference
INFORMATION: Only visible when the optional "coupling monitoring" process data word is activated. | Maximum difference between the mean value of all motor encoders and the external encoders. This value can be used as a wear indicator, as the value increases with wheel wear, for example. |
Index: 50000.189 | |
IEC name: - | |
Decimal places via fieldbus | |
Number of decimal places | Define the number of decimal places for position, speed, acceleration, and jerk via fieldbus. |
Index: 50000.155 (position), 50000.156 (speed), 50000.157 (acceleration), 50000.158 (jerk) | |
IEC name: - | |
Advanced settings | |
Move the "Deactivate external encoders" bit from PO 10 to PO 1 | With this setting, the "Deactivate external encoders" bit can be moved from control word PO 10 bit 13/status word PI 10 bit 13 to control word PO 1 bit 10/status word PI 1 bit 10. |
Index: 50000.184 | |
IEC name: - | |
PROFINET diagnostic alarms | |
Activate diagnostic alarms
INFORMATION: A current device description file must be available for the texts to be displayed correctly. | Send errors and warnings as PROFINET diagnostic alarms so that they can be read in plain text. |
Index: 50000.164 | |
IEC name: - | |
Slot number | Position of the software module on the fieldbus. Slot number 1 corresponds to the 1st freely available slot. For more information, refer to the "Controllers of the MOVI-C® Modular Automation System – Startup with PROFINET/PROFIsafe" manual |
Index: - | |
IEC name: - | |