Process sequence and signal states
INFORMATION

For the behavior of the drive at idle state, observe the information in the "Stop functions" section in the parameterization of the inverter under [Functions] > [Monitoring functions] > [Control functions].
No. | Process | PD | Signal states |
|---|---|---|---|
[1] General enable | PO 1:0 = "1" Enable/emergency stop | PO 1:0 |
|
PO 1:1 = "1" Enable/application stop | PO 1:1 |
| |
PO 1:13 = "0" Output stage inhibit – Signal with highest priority | PO 1:13 |
| |
[1]
| Activation of "jog mode" setpoint application mode | PO 6 | 101 (decimal) |
[1] – [3] | Activation of positive jog direction | PO 1:4 |
|
[4] – [6] | Activation of negative jog direction | PO 1:5 |
|
[1] – [2] and the [4] – [5] | "Rapid speed active" | PI 7:0 | "1": Setpoint speed corresponds to rapid speed specified via PO 2/fixed setpoint. |