Process sequence and signal states

INFORMATION

For the behavior of the drive at idle state, observe the information in the "Stop functions" section in the parameterization of the inverter under [Functions] > [Monitoring functions] > [Control functions].

No.

Process

PD

Signal states

[1]

General enable

PO 1:0 = "1"

Enable/emergency stop

PO 1:0

  • "0": Deceleration with emergency stop ramp
  • "1": Enable

PO 1:1 = "1"

Enable/application stop

PO 1:1

  • "0": Deceleration according to application limit
  • "1": Enable

PO 1:13 = "0"

Output stage inhibit (signal with highest priority)

PO 1:13

  • "0": Output stage enabled
  • "1": Output stage inhibited. The drive coasts to a stop or the brake is applied.

[1]

Activating the "Referencing mode" setpoint application mode

PO 6

300 (decimal)

[2]

Start/stop of reference travel

PO 1:7

  • "0": Stop with drive function FCB 14 (emergency stop)
  • "1": Start of reference travel

[3]

"Active drive referenced" signal

PI 1:5

  • "1": Active drive referenced