Temperature evaluation

WARNING

Dangerous voltages at the terminals of the inverter/power supply module when connecting an unsuitable temperature sensor.
Death or severe injuries due to electric shock.
- To avoid violating the requirements for protective separation, only connect temperature sensors with protective separation to the motor winding to the temperature evaluation.
The temperature sensor can be connected as follows:
- via the encoder cable, which contains the cables of the temperature sensor
- via connections TF1 and GND on terminal X10
- via MOVILINK® DDI to X16
Observe the following additional notes for group and multi-motor drives:
- Preferably use bimetallic temperature switches TH.
- The series connection of the TH contacts (normally closed) is not subject to any restriction if joint monitoring is provided.
- If the TF temperature sensors are available in motors, the temperature sensors of up to 3 motors can be connected in series.