stUserInterface.stConfig

stIN

xWriteConfig

Initiate manual writing of the variables of the mode. The following variables must have been set accordingly:

  • xActivate = TRUE
  • xStart= FALSE

After writing, the variable is reset automatically.

xReadConfig

(reserved)

xResetError

(internal)

eParameter

(internal)

udiAcyclData_RequestData

(internal)

stParameters

 

stOut

xWriteDone

The parameters of the mode have been written (positive edge).

xReadDone

(reserved)

xError

(internal)

bErrorNumber

(internal)

xBusy

(internal)

udiAcyclData_ResponseData

(internal)

 

stIN.stParameters

udiGearFactor

Gear unit factor – corresponds to parameter 8180-02hex in the manual

Initial value: 10000000

uiStandstillThreshold

Upper limit for xStandstill = true

uiMaxMotorCurrent

Limiting upper limit of the permitted current for the I/O module. The real current will not exceed this upper limit.

uiMaxMotorSpeed

(reserved)

Used in other "Motor spec." mode.

diCurrentControllerCurrentLimit

Upper limit of the permitted current for the current controller. Under certain circumstances, the real current may exceed this upper limit.

uiCurrentControllerP_Action

(reserved)

uiCurrentControllerI_Action

(reserved)

uiCurrentControllerFilterFactor

(reserved)

diLagErrorWarningLimit

(reserved)

diLagErrorErrorLimit

(reserved)

uiPositionControllerP_Action

(reserved)

uiPositionControllerI_Action

(reserved)

uiPositionControllerD_Action

(reserved)

uiPositionControllerShiftFactor

(reserved)

uiVelocityControllerP_Action

(reserved)

uiVelocityControllerI_Action

(reserved)

uiVelocityControllerD_Action

(reserved)

uiBlankingTime

(reserved)

uiSupplyVoltage_UndervoltageWarningLevel

(reserved)

uiSupplyVoltage_OvervoltageWarningLevel

(reserved)

uiSupplyVoltage_UndervoltageErrorLevel

(reserved)

uiSupplyVoltage_OvervoltageErrorLevel

(reserved)

iTemperatureMicroControllerWarningLevel

(reserved)

iTemperatureMicroControllerErrorLevel

(reserved)

iTemperaturePowerStageWarningLevel

(reserved)

iTemperaturePowerStageErrorLevel

(reserved)

uiStepperFullStepsPerRevolution

Stepper full steps per revolution – corresponds to parameter 8D00-02hex in the manualUsed in other "Motor spec." mode.

Initial value: 200

uiStepperMicroStepsPerFullStep

Stepper microsteps per full step – corresponds to parameter 8D00-03hex in the manualUsed in other "Motor spec." mode.

Initial value: 8

eEncoderFeedbackConfiguration

uiEncoderResolution