Fault 131 MOVIKIT® – PLCopen general
Fault: 131.0 (8300hex | 33536dec) Description: Initialization of logical device not completed | ||
|---|---|---|
|
| |
Cause | Measure | |
The logical device is not yet ready and does not yet provide data. | Wait until the logical device is initialized and for signal "MC_ReadAxisINfo.CommunicationReady" before performing further actions. | |
Fault: 131.2 (8302hex | 33538dec) Description: Interface not linked | ||
|---|---|---|
|
| |
Cause | Measure | |
Internal error | Contact SEW-EURODRIVE Service. | |
Fault: 131.3 (8303hex | 33539dec) Description: Call only permitted from a task | ||
|---|---|---|
|
| |
Cause | Measure | |
PLCopen blocks that trigger a movement may only be called in one task. | Check whether blocks are called in various tasks. | |
Fault: 131.4 (8304hex | 33540dec) Description: Function not supported | ||
|---|---|---|
|
| |
Cause | Measure | |
A function is selected or a block is called that is not supported by the logical device. | Check whether the function is compatible with the logical device. | |
Fault: 131.5 (8305hex | 33541dec) Description: Function cannot be executed from current state | ||
|---|---|---|
|
| |
Cause | Measure | |
The logical device is in a state (PLCopen State) from which the requested action may not be performed. | Check from which states the call of the desired function is permitted using the PLCopen status diagram. | |