Fault 131 MOVIKIT® – PLCopen general

Fault: 131.0 (8300hex | 33536dec)

Description: Initialization of logical device not completed

 

 

Cause

Measure

The logical device is not yet ready and does not yet provide data.

Wait until the logical device is initialized and for signal "MC_ReadAxisINfo.CommunicationReady" before performing further actions.

Fault: 131.2 (8302hex | 33538dec)

Description: Interface not linked

 

 

Cause

Measure

Internal error

Contact SEW-EURODRIVE Service.

Fault: 131.3 (8303hex | 33539dec)

Description: Call only permitted from a task

 

 

Cause

Measure

PLCopen blocks that trigger a movement may only be called in one task.

Check whether blocks are called in various tasks.

Fault: 131.4 (8304hex | 33540dec)

Description: Function not supported

 

 

Cause

Measure

A function is selected or a block is called that is not supported by the logical device.

Check whether the function is compatible with the logical device.

Fault: 131.5 (8305hex | 33541dec)

Description: Function cannot be executed from current state

 

 

Cause

Measure

The logical device is in a state (PLCopen State) from which the requested action may not be performed.

Check from which states the call of the desired function is permitted using the PLCopen status diagram.