Fault 19 Process data

Error: 19.1 (1301hex | 4865dec)

Description: Torque profile value violation

 

Response: Application stop + output stage inhibit

Cause

Measure

The set torque profile values are not plausible. The torque limit may only be specified as an absolute value.

Correct the profile values.

Error: 19.3 (1303hex | 4867dec)

Description: Speed setpoint violation

 

Response: Application stop + output stage inhibit

Cause

Measure

The speed setpoints in the profile value connection are not plausible. The speed limit may only be specified as an absolute value.

Correct the setpoint.

Error: 19.4 (1304hex | 4868dec)

Description: Acceleration setpoint violation

 

Response: Emergency stop + output stage inhibit

Cause

Measure

The acceleration setpoint in the profile value connection is not plausible. The acceleration limit may only be specified as an absolute value.

Correct the setpoint.

Error: 19.5 (1305hex | 4869dec)

Description: Drive function not available

 

Response: Application stop + output stage inhibit

Cause

Measure

Non-existent drive function (FCB) selected.

Enter the available FCB number.

Error: 19.8 (1308hex | 4872dec)

Description: Drive train changeover not allowed

 

Response: Application stop + output stage inhibit

Cause

Measure

Drive train changeover requested while output stage is enabled.

Inhibit the output stage before changing to another drive train.

Error: 19.9 (1309hex | 4873dec)

Description: Jerk setpoint violation

 

Response: Application stop + output stage inhibit

Cause

Measure

The jerk time is not plausible. The jerk time may only be specified as an absolute value.

Adjust the jerk time.