MDX_MPRO_AppMod_ExtendedPosViaBus_01

The scope data package "MDX_MPRO_AppMod_ExtendedPosViaBus_01" collects supporting scope recordings for the use of the IPOS "Extended bus positioning" application module. The trigger condition is the release of the brake, if present.

Use cases

  • Monitoring of positioning procedures under defined trigger conditions
  • Diagnostics of a reference procedure of the machine

Equipment groups

  • IPOS_extended_positioning_via_bus

Container update interval

  • Trigger: Rising edge DB 00
  • Update interval: 3 h
  • Sample rate: 5 ms
  • Post-trigger recording: 95%

Linked templates

  • AppMod_ExtendedPosViaBus_01

Measurement data

  • Actual speed [min-1]
  • Setpoint speed [min-1]
  • Actual current [%]
  • Relative torque [%]
  • IxT utilization [%]
  • DC link [V]
  • IPOS position H257 (H10257)