MDX_MPRO_AppMod_ModuloPositioning_02

The scope data package "MDX_MPRO_AppMod_ModuloPositioning_02" collects supporting scope recordings for positioning rotational applications (e.g. rotary tables).

Use cases

Equipment groups

  • IPOS_modulo_positioning_via_fieldbus

Container update interval

  • Trigger: Rising edge DB 00
  • Update interval: 3 h
  • Sample rate: 5 ms
  • Post-trigger recording: 95%

Linked templates

  • AppMod_ModuloPositionieurng_02

Measurement data

  • Actual speed [min-1]
  • Setpoint speed [min-1]
  • Actual current [%]
  • Output current [%]
  • DC link [V]
  • IxT utilization [%]
  • Modulo Position [inc.]