Error 131 MOVIKIT® – PLCopen general
Error: 131.0 (8300hex | 33536dec) Description: Still no data available | ||
|---|---|---|
|
| |
Cause | Measure | |
The logical device is not yet ready and is not yet delivering any data | Wait until the logical device is initialized. Query of the MC_ReadAxisInfo.CommunicationReady output | |
Error: 131.2 (8302hex | 33538dec) Description: Interface not linked | ||
|---|---|---|
|
| |
Cause | Measure | |
Internal fault | Contact SEW-EURODRIVE Service. | |
Error: 131.3 (8303hex | 33539dec) Description: Call only permitted from one task | ||
|---|---|---|
|
| |
Cause | Measure | |
PLCOpen blocks that trigger a movement may only be called in one task | Check whether blocks are called in different tasks | |
Error: 131.4 (8304hex | 33540dec) Description: The selected function is not supported | ||
|---|---|---|
|
| |
Cause | Measure | |
A function is selected or a block is called that is not supported by the logical device | Check whether the function is available with the logical device | |
Error: 131.5 (8305hex | 33541dec) Description: The selected function cannot be executed from the current state (PLCopen state) | ||
|---|---|---|
|
| |
Cause | Measure | |
The logical device is in a state from which the requested action is not allowed to be executed. | Check from which states the call of the desired function is permitted using the PLCopen state diagram | |