Error 130 MOVIKIT® – 3D simulation

Error: 130.0 (8200hex | 33280dec)

Description: Interface used invalid

 

 

Cause

Measure

Internal fault

Contact SEW-EURODRIVE Service.

The library version does not match the code-generated IEC project.

– In MOVISUITE®, select [IEC project] in the controller configuration and update the project by clicking "Update IEC project".

– In MOVISUITE®, select [IEC project] in the controller configuration, activate the "Update/recreate software modules" parameter and update the project by clicking "Update IEC project".

Error: 130.1 (8201hex | 33281dec)

Description: Reference used invalid

 

 

Cause

Measure

Internal fault

Contact SEW-EURODRIVE Service.

The library version does not match the code-generated IEC project.

– In MOVISUITE®, select [IEC project] in the controller configuration and update the project by clicking "Update IEC project".

– In MOVISUITE®, select [IEC project] in the controller configuration, activate the "Update/recreate software modules" parameter and update the project by clicking "Update IEC project".

Error: 130.2 (8202hex | 33282dec)

Description: Error communicating with user interface

 

 

Cause

Measure

Internal fault

– Restart the controller.

– Contact SEW‑EURODRIVE Service.

Error: 130.3 (8203hex | 33283dec)

Description: Index outside valid range of values

 

 

Cause

Measure

An attempt was made to connect a user coordinate system to an invalid index (< 1 or > Max.) of the simulation module.

Use a valid index.

Error: 130.4 (8204hex | 33284dec)

Description: Transformation of user coordinate system cannot be retrieved

 

 

Cause

Measure

The coordinate system does not implement the interface correctly.

Correct the implementation of the "GetTransform()" interface.

Error: 130.5 (8205hex | 33285dec)

Description: Not enough kinematic parameters transferred

 

 

Cause

Measure

Not enough kinematic parameters can be read out.

The libraries do not match.

– In MOVISUITE®, select [IEC project] in the controller configuration and update the project by clicking "Update IEC project".

– In MOVISUITE®, select [IEC project] in the controller configuration, activate the "Update/recreate software modules" parameter and update the project by clicking "Update IEC project".

Internal fault

Contact SEW-EURODRIVE Service.

Error: 130.6 (8206hex | 33286dec)

Description: Kinematic model not confirmed by 3D simulation (timeout)

 

 

Cause

Measure

Communication was interrupted during scene setup.

Restart the controller.

Error: 130.7 (8207hex | 33287dec)

Description: Configuration not confirmed by 3D simulation (timeout)

 

 

Cause

Measure

Communication was interrupted during scene setup.

Restart the controller.

Error: 130.8 (8208hex | 33288dec)

Description: Kinematic model not confirmed by 3D simulation

 

 

Cause

Measure

Communication interruption (timeout).

Re-establish connection between RobotMonitor and controller.

Error: 130.9 (8209hex | 33289dec)

Description: Function block calls in communication failed

 

 

Cause

Measure

Diagnostics information

No measure required.

Error: 130.10 (820Ahex | 33290dec)

Description: Missing optional interface

 

 

Cause

Measure

The interface that is not absolutely necessary for displaying the robot is not linked.

– No action required.