Error 108 MOVIKIT® – EncoderInterface

Error: 108.64 (6C40hex | 27712dec)

Description: Configuration parameter missing

 

 

Cause

Measure

Failed to find a required parameter in the configuration file.

– Check the configuration of the individual operating modes.

– In MOVISUITE®, select [Data management] in the controller configuration and download the data by clicking "Update configuration data".

Error: 108.65 (6C41hex | 27713dec)

Description: No external variable linked

 

 

Cause

Measure

No linking of an input variable, a SendObject or an external source to the MOVIKIT® EncoderInterface.

Link input variable.

Error: 108.66 (6C42hex | 27714dec)

Description: Value outside the valid number range

 

 

Cause

Measure

The fault can be caused as follows:

– The multiplication of the number of decimal places and the value in IrSetValue is outside the valid range of values.

– The denominator of the user units set for MOVIKIT® EncoderInterface is 0.

– Set decimal place or IrSetValue smaller.

or

– Set denominator of the user units > 0.

Error: 108.67 (6C43hex | 27715dec)

Description: Filter settings outside the valid number range

 

 

Cause

Measure

Internal fault

Contact SEW-EURODRIVE Service.

Error: 108.68 (6C44hex | 27716dec)

Description: Filter settings outside the valid number range

 

 

Cause

Measure

Internal fault

Contact SEW-EURODRIVE Service.

Error: 108.69 (6C45hex | 27717dec)

Description: Value outside the valid number range

 

 

Cause

Measure

Internal fault

Contact SEW-EURODRIVE Service.

Error: 108.70 (6C46hex | 27718dec)

Description: Interface to the persistent data not linked

 

 

Cause

Measure

Internal fault

Contact SEW-EURODRIVE Service.

Error: 108.71 (6C47hex | 27719dec)

Description: No external variable linked

 

 

Cause

Measure

No linking of the external source.

Link input variable.

Error: 108.72 (6C48hex | 27720dec)

Description: Interface to the configuration data not linked

 

 

Cause

Measure

Internal fault

Contact SEW-EURODRIVE Service.

Error: 108.73 (6C49hex | 27721dec)

Description: Interface not linked

 

 

Cause

Measure

Internal fault

Contact SEW-EURODRIVE Service.