Digital inputs

INFORMATION

The initial state of the assignment is "Default with HW limit switches".

Input

Function (default with HW limit switches)

Function (default without HW limit switches)

Function
(freely configurable)

DI00

Input is internally jumpered to 24 V voltage supply

DI01

HW negative
limit switch

No function/
freely configurable

Freely configurable

DI02

HW positive
limit switch

No function/
freely configurable

Freely configurable

DI03

Reference cam

Reference cam

Freely configurable

DI04

No function/touchprobe inputWhen "sensor-based positioning" additional mode is selected

No function or freely configurable/touchprobe inputWhen "sensor-based positioning" additional mode is selected

Freely configurable/touchprobe inputWhen "sensor-based positioning" additional mode is selected