Process sequence and signal states

INFORMATION

For the behavior of the drive at standstill, observe the information in section "Stop functions" in the "Control functions" configuration menu of the inverter.

No.

Procedure

PD

Signal states

[1]

General enable

  • PO 1:0 = "1"
  • Enable/emergency stop

PO 1:0

  • "1": Enable
  • "0": Deceleration with emergency stop ramp
  • PO 1:1 = "1"
  • Enable/application stop

PO 1:1

  • "1": Enable
  • "0": Deceleration according to application limit
  • PO 1:13 = "0"
  • Output stage inhibit (signal with highest priority)

PO 1:13

  • "0": Output stage enabled
  • "1": Output stage inhibited (the drive coasts to a stop or the brake is applied)

[1]

"Referencing mode" selected

PO 6

300/301 (decimal)

[2]

Start/stop of reference travel

PO 1:7

  • "1": Reference travel start
  • "0": Stop with drive function FCB 26 (Stop at user-defined limits).

[3]

Signal

"Active drive referenced"

PI 1:5

  • "1": "Active drive referenced"