Terminal assignment for MGF..1-DSM-C
Observe the wiring instructions in the documentation of the frequency inverter that you use.
Attach units without a plug connector to the terminals as follows:
- De-energize the device. Pay attention to the 5 safety rules in chapter “Carrying out electrical work safely”.
- Secure the output shaft against rotation. In this way, you will avoid electric shocks caused by regenerative operation when the shaft is turned.
- Loosen the screws of the cover. Remove the cover.
- Route the cables through the cable glands into the connection box.
- Connect the unit in accordance with the following terminal assignment.
The following figure shows the terminals of MOVIGEAR® MGF..1-DSM-C:
Terminal | Name | Function | |
---|---|---|---|
X2 | PE | PE connection | |
W | Phase W | ||
V | Phase V | ||
U | Phase U | ||
PE | PE connection | ||
X10_A | KTY PK | + | Temperature sensor PK (Pt1000) + |
KTY PK | - | Temperature sensor PK (Pt1000) - |