Terminal assignment for MGF..1-DSM-C

Observe the wiring instructions in the documentation of the frequency inverter that you use.

Attach units without a plug connector to the terminals as follows:

  1. WARNING! Electric shock caused by dangerous voltages in the connection box. Severe or fatal injuries. De-energize the device. Pay attention to the 5 safety rules in chapter “Carrying out electrical work safely”.
  2. Secure the output shaft against rotation. In this way, you will avoid electric shocks caused by regenerative operation when the shaft is turned.
  3. Loosen the screws of the cover. Remove the cover.
  4. Route the cables through the cable glands into the connection box.
  5. Connect the unit in accordance with the following terminal assignment.

The following figure shows the terminals of MOVIGEAR® MGF..1-DSM-C:

Terminal

Name

Function

X2
terminals for motor connection

PE

PE connection

W

Phase W

V

Phase V

U

Phase U

PE

PE connection

X10_A
terminals for temperature sensor

KTY PK

+

Temperature sensor PK (Pt1000) +

KTY PK

-

Temperature sensor PK (Pt1000) -