Fieldbus interface

Parameter name

Description

Fieldbus configuration

Activate fieldbus connection

  • Yes
  • No

Index: 50000.150

IEC name: -

Start address

Start address of the fieldbus process data words in the array of the bus system. Counting starts at 1.

Index: 50000.151

IEC name: -

Basic process data

Number of process data for the software module without additionally set belts
(e.g. group + 1 telescope + 1 belt = 32 PD)

Index: 50000.159

IEC name: -

Process data of functions in use

Attach an additional process data word for each function used.

Index: 50000.161

IEC name: -

Optional process data

Number of additional belts (up to 3 more) appended with 10 process data words each

Index: 50000.163

IEC name: -

Additional process data

Additional process data that is not occupied by the software module and can be freely assigned by the user. The assignment of these process data must be programmed in the IEC program.

Index: 50000.160

IEC name: -

Process data length

Length of the process data of the software module

Index: -

IEC name: -

Decimal places via fieldbus

Number of decimal places

Define the number of decimal places for position, speed, acceleration, and jerk via fieldbus.

Index: 50000.155 (position), 50000.156 (speed), 50000.157 (acceleration), 50000.158 (jerk)

IEC name: -