Software limit switches

Parameter name

Value

Software limit switches

Monitoring
negative SW limit switch

  • On
  • Activate monitoring of negative software limit switch
  • Off
  • Deactivate monitoring of negative software limit switch

Index: 8572.3

IEC name: LimitSwitchEvaluation.SoftwareLimitSwitch.In.xActivateMonitoringNegative

Negative SW limit switch

Position of the negative software limit switch

(in user units)

Index: 8572.4

IEC name: LimitSwitchEvaluation.SoftwareLimitSwitch.In.lrLimitNegative

Monitoring
positive SW limit switch

  • On
  • Activate monitoring of positive software limit switch
  • Off
  • Deactivate monitoring of positive software limit switch

Index: 8572.5

IEC name: LimitSwitchEvaluation.SoftwareLimitSwitch.In.xActivateMonitoringPositive

Positive SW limit switch

Position of the positive software limit switch

(in user units)

Index: 8572.6

IEC name: LimitSwitchEvaluation.SoftwareLimitSwitch.In.lrLimitPositive

Fault response

SW limit switch hit response

  • No response
  • Emergency stop + output stage inhibit
  • Emergency stop + output stage inhibit with self-reset

Index: 8572.2

IEC name: Parameter.LimitSwitchData1.SwLsHitResp