Process sequence and signal states
INFORMATION
For the behavior of the drive at standstill, observe the information in the section "Stop functions" in the "Control functions" configuration menu of the inverter.
No. | Procedure | PD | Signal states |
---|---|---|---|
[1] General enable |
| PO 1:0 |
|
| PO 1:1 |
| |
| PO 1:13 |
| |
[1] | Activation of "jog mode" target application mode | PO 6 | 100/101 (decimal) |
Dynamic parameters are applied (also during ongoing movement) | PO 2 PO 3 PO 4 | Setpoint speed Acceleration Deceleration | |
[2] to [4] | Activation of positive jog direction | PO 1:4 |
|
[5] to [7] | Activation of negative jog direction | PO 1:5 |
|
[3] to [4] and [6] to [7] | If the actual speed lies within the configured window width, the feedback "Setpoint/actual speed comparison" is issued. | PI 1:11 |
|