Process input data

The following table shows the process input data from the inverter to the PLC for control via fieldbus with 8 process data words.

INFORMATION

The "V/P" column indicates whether the respective process data word or bit is only available when using MOVIKIT® Positioning Drive (P) or whether it is also available when using MOVIKIT® Velocity Drive (V/P).

Word

Bit

V/P

Function

PI 1

Status word

0

V/P

"1": Ready for operation

1

V/P

"1": STO inactive

2

V/P

"1": Output stage enable

3

V/P

"1": Brake released

4

V/P

"1": Motor running (motor standstill active)

5

V/P

"1": Active drive referenced

6

V/P

"1": New relative position applied

7

V/P

"1": "In position" signal active

8

V/P

"1": Fault

9

V/P

"1": Warning

"Warning" can be defined as a response to certain faults. If a warning is signaled, both bit PI 1.9 and the associated fault code are indicated in PI 3. If a warning and a fault are active at the same time, only bit PI 1.8 is set and the respective fault code is indicated in PI 3.

10

V/P

"1": Drive train 2 active

11

V/P

"1": "Setpoint/actual speed comparison" signal active

12

V/P

"1": Software limit switches inactive

13

V/P

"1": Reserved

14

V/P

"1": Standby mode active

15

V/P

MOVIKIT® Handshake Out (for details, see MOVIKIT® Handshake In)

PI 2

Actual speed

0 – 15

V/P

User unit

PI 3

Status

Fault.Subfault

0 – 15

V/P

  • No fault: Display of current FCB (low byte)
  • Device fault: Display of device fault code
  • Fault in option: Display of option fault code

(High byte: fault; Low byte: subfault)

For more information, refer to the product manual of the respective device.

PI 4

Actual torque

0 – 15

V/P

  • Actual torque related to the nominal motor torque (unit: 0.1%)
  • Relative apparent current based on the nominal inverter current (unit: 0.1%)
  • Absolute apparent current (unit: 0.1 A)

PI 5

Digital inputs

0

V/P

DI 00

...

V/P

...

7

V/P

DI 07

...

V/P

...

9

V/P

DI 09 / DIO 01 (input)

10

V/P

DI 10 / DIO 02 (input)

...

V/P

...

13

V/P

DI 13

...

V/P

...

PI 6

Actual application mode

0 – 15

P

Operating mode (see Operating modes)

PI 7

Actual position (high word)

0 – 15

P

User unit

PI 8

Actual position (low word)

0 – 15

P

User unit