Energy storage discharge
INFORMATION

Only available with MDP92A.
Parameter group | Description |
|---|---|
Energy storage discharge INFORMATION: If the parameters are not set correctly (e.g. 0 kW), the software module signals a fault when activating the "Energy storage discharge" operating mode and the operating mode cannot be used. | |
External resistor – resistance | Ohmic resistance of connected braking resistor according to data sheet. Default value: 12 Ohm |
External resistor – maximum continuous power | Continuous power that can be dissipated in heat in kW according to data sheet. Default value: 0.0 kW |
Brake chopper switch-on threshold | Voltage limit from which an attempt is made to limit the voltage by switching on the brake chopper. Default value: 860 000 V |
Brake chopper hysteresis | Voltage difference to the switch-on threshold of the brake chopper for switching off again. Default value: 30 000 V |