Energy storage discharge

INFORMATION

Only available with MDP92A.

Parameter group

Description

Energy storage discharge

INFORMATION: If the parameters are not set correctly (e.g. 0 kW), the software module signals a fault when activating the "Energy storage discharge" operating mode and the operating mode cannot be used.

External resistor – resistance

Ohmic resistance of connected braking resistor according to data sheet.

Default value: 12 Ohm

External resistor – maximum continuous power

Continuous power that can be dissipated in heat in kW according to data sheet.

Default value: 0.0 kW

Brake chopper switch-on threshold

Voltage limit from which an attempt is made to limit the voltage by switching on the brake chopper.

Default value: 860 000 V

Brake chopper hysteresis

Voltage difference to the switch-on threshold of the brake chopper for switching off again.

Default value: 30 000 V