Enabling the direction of rotation on MOVIMOT®

Observe the correct connection of "24V" and "⊥" and verify by testing!

Variant 1

  • Both directions of rotation are enabled.

Variant 2

  • Clockwise direction of rotation is enabled.

Variant 3

  • Counterclockwise direction of rotation is enabled.

 

[1]

Safe 24 V supply
from the safety relay

[2]

Safety contacts

[3]

Jumper in the connection box
(no switch)

Safety contact "24V" [1] is marked in red.

Safety contact "⊥" [2] is marked in blue.