Startup

You can find an overview of which motors you can start up with the CBG01A keypad in the Range of functions chapter. To start up other motors, use the CBG21A keypad or the MOVISUITE® engineering software.

If you have already performed a startup with a CBG21A keypad or the MOVISUITE® engineering software, access to the drive train with the keypad is blocked.

A universal motor data set with the same performance is preloaded at the factory. If you require better control performance or if the connected motor deviates from the inverter power, you must perform startup and enter the motor data. Enter the following information in the individual steps according to the nameplate of the connected motor.

7-segment display

Specification

Unit / selection

Drive train

DT1/DT2

Nominal motor voltage

V

Nominal motor current

A

Frequency

Hz

Power

kW

Power factor cos φ

Nominal motor speed

min-1

Control mode

  • V/fMOVITRAC® advanced and MOVITRAC® classic
  • VFCPLUSMOVITRAC® advanced and MOVITRAC® classic
  • LVFCMOVITRAC® basic

Brake

With brake, without brake

Motor temperature evaluation

TF, TH, no sensor

INFORMATION

Depending on the firmware version, the keypad displays Care (< V4.00) or Attention (as of V4.00).
"Startup" sequence