Startup
You can find an overview of which motors you can start up with the CBG01A keypad in the Range of functions chapter. To start up other motors, use the CBG21A keypad or the MOVISUITE® engineering software.
If you have already performed a startup with a CBG21A keypad or the MOVISUITE® engineering software, access to the drive train with the keypad is blocked.
A universal motor data set with the same performance is preloaded at the factory. If you require better control performance or if the connected motor deviates from the inverter power, you must perform startup and enter the motor data. Enter the following information in the individual steps according to the nameplate of the connected motor.
7-segment display | Specification | Unit / selection |
|---|---|---|
Drive train | DT1/DT2 | |
Nominal motor voltage | V | |
Nominal motor current | A | |
Frequency | Hz | |
Power | kW | |
Power factor cos φ | – | |
Nominal motor speed | min-1 | |
Control mode |
| |
Brake | With brake, without brake | |
Motor temperature evaluation | TF, TH, no sensor |
INFORMATION