Encoder coupling
Parameter designation | Description |
|---|---|
Coupling monitoring between external encoder [A] and motor encoder [B] | |
Mechanical connection type INFORMATION: See also Monitoring of encoder couplings. | Select the connection type of the encoder coupling. Depending on the selected value, additional settings fields are displayed.
Default value: Friction contact |
Index: 50013.27 | |
IEC name: – | |
Absolute error window | Permitted difference between the mean position value of all motor encoders and the mean position value of all external encoders (in user units). To deactivate monitoring of the absolute error window, enter "0". For the configuration, it is recommended to perform a measurement run and read out the maximum value of the coupling error. Default value: 0 |
Index: 50013.21 | |
IEC name: Controller.EncoderEvaluation.Config.CouplingObserver.lrAbsoluteErrorDistanceWindow | |
Absolute warning window | Permitted difference between the mean position value of all motor encoders and the mean position value of all external encoders (in user units). To deactivate monitoring of the absolute warning window, enter "0". Default value: 5 motor revolutions (in user units) |
Index: 50013.22 | |
IEC name: Controller.EncoderEvaluation.Config.CouplingObserver.lrAbsoluteWarningDistanceWindow | |
Slip error window INFORMATION: Only visible if the mechanical connection type is "friction contact". | Allowed slip relative to the movement of the motor encoder up to the error message. To deactivate monitoring of the slip error window, enter "0". Default value: 0% |
Index: 50013.23 | |
IEC name: Controller.EncoderEvaluation.Config.CouplingObserver.lrSlipRelationErrorWindow | |
Slip warning window INFORMATION: Only visible if the mechanical connection type is "friction contact". | Allowed slip relative to the movement of the motor encoder up to the warning message. To deactivate monitoring of the slip warning window, enter "0". Default value: 5% |
Index: 50013.24 | |
IEC name: Controller.EncoderEvaluation.Config.CouplingObserver.lrSlipRelationWarningWindow | |
Slip period INFORMATION: Only visible if the mechanical connection type is "friction contact". | When the slip period has ended, the calculated current slip is reset. If the "Slip warning window" or "Slip error window" parameters are used, the slip period must be greater than 0. The recommended value is one tenth of a travel cycle (in user units). The slip period is important in order to limit the maximum coupling error caused by slip. See Monitoring of encoder couplings. Default value: 50 motor revolutions (in user units) |
Index: 50013.25 | |
IEC name: Controller.EncoderEvaluation.Config.CouplingObserver.lrSlipDistancePeriod | |
Reset on restart INFORMATION: Only visible in expert mode and when the mechanical connection type is "friction contact". |
|
Index: 50013.26 Bit0 | |
IEC name: Controller.EncoderEvaluation.Config.CouplingObserver.xDeleteDistanceWithEnableEdge | |