Process sequence and signal states
For information on the drive's behavior at standstill, refer to the specifications for the "Stop functions" in the "Functions" > "Monitoring functions" > "Control functions" configuration menu of the inverter.
No adjustment process is performed in the module positive synchronous operation control (1002) and module negative synchronous operation control (1003) operating modes if the master actual position is within the configured adjust window. The "Adjustment process completed" (PI 9:3) signal is immediately set. Note that a value > 0 must be configured for the adjust window in order for an unintended compensation movement to be executed according to the selected operating mode.
No. | Sequence | PD | Signal states |
|---|---|---|---|
[1] General enable |
| PO 1:0 |
|
| PO 1:1 |
| |
| PO 1:13 |
| |
[1] | Selection of operating mode | PO 6 |
|
[1] to [2] | Start/stop of the adjustment process | PO 1:7 |
|
Adjustment process is active | PI 9:2 |
| |
[2] | Adjustment process is finished | PI 9:3 |
|
In adjust window (In AdjustWindow)
- 0: The actual master position is outside the configured adjust window.
- 1: The actual master position is within the configured adjust window.
Note that the In AdjustWindow can only be calculated correctly for modulo axes if the same modulo range has been configured for them.