Control word
For information on the drive's behavior at standstill, refer to the information in chapter Control functions.
Bit | Function | PD | Description |
|---|---|---|---|
0 | Enable/emergency stop | PO 1:0 |
|
1 | Enable/application stop | PO 1:1 |
|
2 | Reserved | PO 1:2 | – |
3 | Release brake (without enable) | PO 1:3 | If required, activate this function using parameter 8501.2 (Release brake/DynaStop® with FCB 01 – enable). |
4 | Jog positive | PO 1:4 | Signal for moving the drive in positive direction in jog mode. |
5 | Jog negative | PO 1:5 | Signal for moving the drive in negative direction in jog mode. |
6 | Apply relative position | PO 1:6 | Apply relative target position in relative positioning mode (401). This signal is ineffective for all the other operating modes. |
7 | Start/stop with fieldbus ramp | PO 1:7 |
|
8 | Fault reset | PO 1:8 | Reset of error messages with the positive edge of the signal. |
9 | Reserved | PO 1:9 | – |
10 | Activate drive train 2 | PO 1:10 |
|
11 | Reserved | PO 1:11 | – |
12 | Deactivate SW limit switches | PO 1:12 | Prerequisite: SW limit switches are activated and configured.
|
13 | Activate output stage inhibit | PO 1:13 |
|
14 | Activate standby mode | PO 1:14 |
Standby mode can only be activated when the output stage is inhibited. |
15 | MOVIKIT® Handshake In | PO 1:15 | This signal is copied internally to status word bit 15 (MOVIKIT® Handshake Out). If the copying operation fails ("Handshake Out" remains constant with changing "Handshake In" signal), the device-internal processing of the MOVIKIT® software module is disrupted. |