Fieldbus interface

 

Parameter designation

Description

Fieldbus configuration

Activate fieldbus connection

Activate the fieldbus connection and automatically add the MOVIKIT® fieldbus monitor for monitoring and controlling the fieldbus interface to the IEC project.

Index: 50000.150

IEC name: –

Start address

Start address of the process data in the array of the bus system

Default value: 1

Index: 50000.151

IEC name: –

Basic process data

Amount of process data for the software module without activated "Additional functions" or optional process data

Index: 50000.159

IEC name: –

Process data of additional functions

Additional process data of the activated "Additional functions"

Index: 50000.161

IEC name: –

Process data for additional process values of the inverter

Additional process values of the inverter

Index: 50000.104

IEC name: -

Optional process data

Additional process data of the activated "Optional process data"

Index: 50000.163

IEC name: –

Additional process data user program

Additional process data that is not occupied by the software module and can be freely assigned by the user. The assignment of this process data must be programmed in the IEC program.

Index: 50000.160

IEC name: -

Process data length

Resulting length of the process data of the software module

Index: 50000.152

IEC name: –

Optional process data

Control word/status word position controller

INFORMATION: Only visible if the additional function "Position controller" is activated.

Activate position controller or external encoder.

Default value: Off

Index: 50000.186, Bit0

IEC name: –

Anti-sway control

INFORMATION: Only visible if the additional function "Position controller" is activated.

Show additional optional process data for the "Anti-sway control" function.

Default value: Off

Index: 50000.174, Bit0

IEC name: –

Status word/control word

INFORMATION: Only visible when the optional process data word "Anti-sway control" is activated.

Activate anti-sway control and activate feedback whether anti-sway control is active.

Default value: Off

Index: 50000.175, Bit0

IEC name: –

Payload mass

INFORMATION: Only visible when the optional process data word "Anti-sway control" is activated.

Activate order-related modification of the payload configuration.

Default value: Off

Index: 50000.176, Bit0

IEC name: –

Distance between lifting and traveling trolley

INFORMATION: Only visible when the optional process data word "Anti-sway control" is activated.

Activate order-related change of the "Distance between lifting and traveling trolley".

Default value: Off

Index: 50000.177, Bit0

IEC name: –

Actual position of external encoder

INFORMATION: Only visible if the additional function "Position controller" is activated.

Activate actual position of the external encoder without integration of the motor encoder for position controller in combined operation.

Default value: Off

Index: 50000.187, Bit0

IEC name: –

Advanced settings

Decimal places via fieldbus

Defining the number of decimal places via fieldbus for:

  • Position
    Default value: 2
  • Speed
    Default value: 0
  • Acceleration
    Default value: 0
  • Jerk
    Default value: 0

INFORMATION: Negative values can also be set for the jerk. These then correspond to the pre-decimal places of the jerk. For example, if -1 is set for the number of decimal places and 1000 is set for the jerk, a jerk of 10 000 results. Even jerk values greater than 16 bits can therefore be traveled.

Index: 50000.155 (position), 50000.156 (speed), 50000.157 (acceleration), 50000.158 (jerk)

IEC name: –

PROFINET diagnostic alarms

INFORMATION: A current device description file must be available for the texts to be displayed correctly.

Send errors and warnings as PROFINET diagnostic alarms so that they can be read in plain text.

Default value: Off

Index: 50000.164, Bit0

IEC name: –

Slot number

INFORMATION: Only available if PROFINET diagnostic alarms are activated.

Position of the software module on the fieldbus. Slot number 1 corresponds to the 1st freely available slot after the reserved slots for safe communication.

For more information, refer to the "Controllers of the MOVI-C® Modular Automation System – Startup with PROFINET/PROFIsafe" manual

Default value: 0.000

Index: 50000.165

IEC name: –

Fieldbus interface

Overview of the resulting process data assignment