Limit values
Parameter designation | Description |
|---|---|
Application limits for controller functions | |
Jerk | The setpoint jerk specified via process data word PO 9 is limited to the jerk configured here. In addition, this parameter is used for stopping via the central stop profile of the software module. Default value: 0 |
Index: 50041.05 | |
IEC name: – | |
Variable torque limit Q1 | |
Minimum torque limit | The specified torque limit is limited by this value. This also applies if a value of 0 is specified. (in % of nominal motor torque) Default value: 50.0% nominal motor torque |
Index: 50040.21 | |
IEC name: TorqueLimitation.Config.lrMinimumTorqueLimit | |
Use torque limits from profile value connection INFORMATION: Can only be configured starting with version 9 of the inverter firmware. |
|
Index: 8563.2 Bit0 | |
IEC name: – | |