Selecting the cooling system
If the thermal rating PT of a gear unit is not sufficient with cooling by fan, water cooling cover, or water cooling cartridge, you can use a cooling system with circulation cooling; see chapter Cooling.
The proper size of the cooling system can be determined by approximation by means of the power loss PV of the gear unit.
The power loss PV of the gear unit must be smaller than the cooling capacity of the cooling system.
PV< cooling capacity of cooling system in kW
In addition, the selection of the appropriate cooling system depends on the following factors:
- Actual power loss to be cooled
- Present cooling water temperature and volume flow
- Ambient temperature
- Ratio of oil quantity in the gear unit to oil volume flow of cooling system > 2
Contact SEW-EURODRIVE to select the suitable circulation cooling for your ambient conditions.