Sizes X170 – 320

  1. Loosen the retaining screw [6].
  2. [6]

    Retaining screw

  3. Remove the retaining screws [3] and the end plate [4].
  4. [3]

    Retaining screw

    [4]

    End plate

  5. To protect the centering bore, screw the retaining screw [6] into the machine shaft [1].
  6. [1]

    Machine shaft

    [6]

    Retaining screw

  7. To disassemble the gear unit, flip the end plate [4] over and use the retaining screws [3] to reattach it centrically to the hollow shaft [7]. The retaining screws [3] should be tightened hand-tight.
  8. [3]

    Retaining screw

    [4]

    End plate

    [7]

    Hollow shaft

  9. Thread the ejector screw [8] into the end plate [4] to remove the gear unit from the machine shaft [1]. Applying lubricant to the ejector screw [8] and the thread in the end plate [4] prior to disassembly makes the job easier.
  10. [1]

    Machine shaft

    [4]

    End plate

    [8]